AWG to mm Diameter Chart (and mm² to AWG)

By Hassan Nawaz, B.Sc. Electrical Engineering. Updated November 11, 2026.

The diameter of 6 gauge wire is 0.162 in or 4.11 mm, and of 12 gauge wire 0.0808 in or 2.05 mm. The chart below gives every size, with the cross-section area you need to compare against metric cable. For ampacity, see the wire gauge chart.

AWG to mm diameter chart

Values are for the bare conductor, solid copper, not including insulation. The overall cable is larger.

AWGDiameter (in)Diameter (mm)Area (mm²)Circular mils
4/00.460011.684107.22211,600
3/00.409610.40585.03167,800
2/00.36489.26667.43133,100
1/00.32498.25153.48105,600
10.28937.34842.4183,690
20.25766.54433.6366,360
30.22945.82726.6752,620
40.20435.18921.1541,740
60.16204.11513.3026,240
80.12853.2648.3716,510
100.10192.5885.2610,380
120.08082.0533.316,530
140.06411.6282.084,110
160.05081.2911.312,580
180.04031.0240.821,620
200.03200.8120.521,022
220.02530.6440.33642
240.02010.5110.20404
260.01590.4050.13254
280.01260.3210.08160
300.01000.2550.05101

Common gauges at a glance

GaugeDiameterAreaWhere you see it
6 AWG0.162 in (4.12 mm)13.3 mm²Ranges, sub panels, ground wire for service
8 AWG0.128 in (3.26 mm)8.4 mm²Large AC units, EV chargers
10 AWG0.102 in (2.59 mm)5.3 mm²Dryers, water heaters
12 AWG0.081 in (2.05 mm)3.3 mm²20 A household circuits
14 AWG0.064 in (1.63 mm)2.1 mm²Lighting, 15 A circuits
18 AWG0.040 in (1.02 mm)0.82 mm²Thermostat, doorbell, low-voltage

AWG diameter formula

Diameter (in) = 0.005 × 92(36 − n) ÷ 39
Diameter (mm) = 0.127 × 92(36 − n) ÷ 39

Here n is the gauge number. For the aught sizes, 1/0 counts as 0, 2/0 as −1, 3/0 as −2 and 4/0 as −3. Example: 12 AWG gives 0.127 × 920.615 = 2.05 mm. The area is the circle area, π ÷ 4 × diameter²: 3.31 mm² for 12 AWG.

mm² to AWG conversion

European and international cable is sold by cross-section area. The nearest AWG by area is shown below. The two systems do not line up exactly, and for safety-critical work you should choose the size whose ampacity meets the load rather than only the closest area.

Metric sizeNearest AWGAWG area (mm²)
0.5 mm²20 AWG0.52
0.75 mm²18 AWG0.82
1 mm²17 AWG1.04
1.5 mm²15 AWG1.65
2.5 mm²13 AWG2.62
4 mm²11 AWG4.17
6 mm²9 AWG6.63
10 mm²7 AWG10.55
16 mm²5 AWG16.77
25 mm²3 AWG26.67
35 mm²2 AWG33.63
50 mm²1/053.48
70 mm²2/067.43
95 mm²3/085.03

Need current limits instead of dimensions? Use the wire size calculator, which checks ampacity and voltage drop.

Frequently asked questions

What is the diameter of 6 gauge wire?

0.162 inches or 4.11 mm for solid bare copper, with a cross-section of 13.3 mm².

What is 12 gauge wire in mm?

2.05 mm in diameter, or 3.31 mm² in area.

How many mm² is 10 AWG?

5.26 mm².

Is 2.5 mm² the same as 12 AWG?

Not exactly. 2.5 mm² sits between 14 AWG (2.08 mm²) and 12 AWG (3.31 mm²) and is closest to 13 AWG (2.63 mm²). Check the ampacity of the cable you actually have rather than substituting by name.

Sources

Calculators for this

Last updated November 11, 2026. Values follow published tables. How we check our data. Found an error? Tell us.